Replacment Bulbs

 

Light bulbs in microscope illuminators need to be replaced periodically. The bulbs on this page are most commonly used in Meiji Techno illumination systems. If you own a Meiji microscope and need a replacement, you should be able to purchase it at your local Meiji Dealer. Some of the older models or specialized microscopes may use bulbs not listed here. If you cannot find the correct bulb, contact our technical support staff will be happy to assist you.

 
 

 

MA111

MA260/05

MA261/SL-10

MA263/05
MA263/10

MA264/05

MA275/05

Part Number
Description
Application
MA111
12V 10W

Incident light: ST-3, SKT-1B, SKT-2B, SKT-3B, GS2000

Incident & transmitted light: SKT-BT, SKT-2BT, SKT-3BT

Transmitted light: STC-3

MA260/05
6V 20W Halogen      
For MA260, MA264H, and MA264EX illuminators
MA261/SL-10
115V 20W
For "B" Stand and MA261/35 (TM200 Series illuminator)
MA263/05
115V 30W 
For MA263 illuminators
MA263/10
220/240V 30W
For MA263 illuminators
MA264/05
6.5V 2.75A
For MA264 illuminators
MA275/05
12V 50W
For ML5000 Series 50W models; ML7500, ML8500 and MX7500, MX8500 series.
 
 

MA305/05 
MA309/05
MA326
MA350/10
MA350/20
MA361/10
MA362/10

 

Part Number
Description
Application 
MA309/05
4W Tube Fluorescent
For MA309 fluorescent box illuminators for GEM stand 
MA305/05
8W Ring Fluorescent
For MA305/100, MA305/200 ring fluorescent illuminators 
MA326
6V 30W Halogen      
For ML5000 Series 30W models; all VT, IM7000, ML2000, ML7000, ML8000, ML9000 , MX4000, MX5000, MX6000, MX7000, MX8000, MX9000 Series models; all RZT & RZDT Stands
MA350/10
115V 30W
For GEM stand transmitted light
MA350/20
220/240V 30W
For GEM stand transmitted light
MA361/10
110V 20W
Half-silvered bulb for TM400 Series 20W models
MA362/10
115V 30W
Half-silvered bulb for TM400 Series 30W models
 
 

MA560
MA561
MA570
FL180/70
FL150/70
MA357
MA358

 

Part Number
Description
Application 
MA560 6V 1.2A Tungsten Incident light: AB, ABZ, PB Stands
All BM/BMK Series models
MA561 6V 1.2A Tungsten Transmitted light: AB, ABZ, PB Stands Note: MA560 and MA561 may appear to be identical, but they are not interchangeable.
MA570 6V 10W Halogen     Incident & transmitted light: ABE, ABH, ABZH, PBH Stands
FL150/70
21V 150W Halogen  For Fiber Optic Light sources: All FT190 and FL150 Series
FL180/70 21V 150W Halogen For FL180, FL181 & FL182 fiber optic illuminators
MA357 8V 12W Tungsten  Frosted - Fits Meiji Techno MT5500 Series Microscopes
MA358 8V 12W Tungsten Clear - Fits Meiji Techno MT5500 Series Microscopes
MA590  110V 15W Tungsten Frosted - Fits Meiji Techno PBM Series Stands
 
 

 

DC Arc Lamps

 

Part Number  
Description    
Applications
BA005
HBO 100W Mercury DC Arc Lamp
TC5000 Series &
MX6000 Series
Equipped with
Epi-Fluorescence Lamphouses
BA013
XBO 75W Xenon DC Arc Lamp  
BA014
XBO 100W Xenon DC Arc Lamp      
 
 

Tips on extending bulb life

Bulbs have a rough life in a microscope: burning in an enclosed area for hours on end with a finite lifetime, the effects of too much heat and not enough ventilation, DC current from the dimmer circuit slowly thinning the metal of the filament. And with bulbs nowadays being manufactured more and more cheaply, the cumulative effect is not good.

With all that been said, if you have the option of slowly turning up the brightness, then do so. If the bulb is halogen or DC Arc Lamp type, DO NOT TOUCH THE GLASS with your bare hands when installing bulbs. Use the plastic bag it comes in to install the bulb. DO NOT jar or bump or run your scope in an environment that has excessive vibration. Turn your scope off if you do not need it on. Some bulbs have a rated life of only 100 - 200 hours so if you use your scope full time, be prepared to use bulbs.

Halogen bulbs in microscopes and fiber optic light sources can also have problems if the socket is worn out; i.e. the connection cannot sink enough heat away from the bulb and/or the electrical connection is weak. If your scope is an old workhorse who's starting to eat bulbs, check the bulb socket out for poor contact and discoloration of the contact. The bi-pin type bulb should push stiffly into the socket. If not, or if it wobbles around, the socket is too old and needs replacement.